Board not appearing as a COM port

Install the CP210x driver: CP210x_Universal_Windows_Driver.zip. Try a different USB cable (some cables are charge-only and carry no data), and try a different USB port on your computer.

Connection drops unexpectedly

You should disable the power saving feature of the USB port. In Device Manager, find the CP210x device under Ports (COM & LPT), open its Properties → Power Management, and uncheck "Allow the computer to turn off this device to save power".

Cannot connect over WiFi

  • Verify the IP address; check your router's DHCP table, or reconnect via USB to see the current address shown in Initial motor configuration and settings.
  • Make sure the board and the PC are on the same network.
  • Check that no firewall is blocking UDP port 10000.
  • Confirm that Station mode is enabled and the board has successfully joined your network.

Shutter board not connecting

  • The rotator↔shutter link is a private, internal Wi-Fi connection that pairs automatically—no network settings to check here. If it is not coming up, power-cycle both boards.
  • Make sure both boards are powered and within range of each other.
  • Initial motor configuration and settings waits up to 30 seconds for the shutter, be patient after connecting the rotator.